206 Jones Blvd. Pottstown, PA 19464 USA
Phone: 610-495-0110 : 800-223-2629
www.micro-coax.com |
UT-141-SA-AL-M17 |
|
Handformable Aluminum
Jacketed Cable |
|
MECHANICAL
CHARACTERISTICS |
|
|
| Outer Conductor Diameter, inch
(mm) |
0.141+/-0.001
(3.581+/-0.0254)
|
| Dielectric Diameter, inch
(mm) |
0.1175
(2.985) |
| Center Conductor Diameter, inch
(mm) |
0.0359+/-0.0005
(0.912+/-0.0127) |
| Maximum Length, feet
(meters) |
20
(6.1) |
| Minimum Inside Bend Radius, inch
(mm) |
0.125
(3.175) |
| Weight, pounds/100 ft.
(kg/100 meters) |
1.88
(2.82) |
|
ELECTRICAL
CHARACTERISTICS |
|
|
| Impedance, ohms |
50+/-1.0 |
| Frequency Range |
DC-20 |
| Velocity of Propagation |
70 |
| Capacitance, pF/ft.
(pF/meter) |
29 |
Typical Insertion Loss,
dB/100 ft. (dB/meter)
and Average Power Handling, Watts CW at 20
degrees Celsius and Sea level |
Frequency |
Insertion Loss |
Power |
0.5 GHz
1.0 GHz
5.0 GHz
10.0 GHz
20.0 GHz |
0.08 (0.28)
0.12 (0.40)
0.29 (0.96)
0.44 (1.45)
0.67 (2.20) |
439.2
305.7
128.2
86.6
57.6 |
| Corona Extinction Voltage, VRMS @ 60 Hz |
1900 |
| Voltage Withstand, VRMS @ 60 Hz |
5000 |
|
ENVIRONMENTAL
CHARACTERISTICS |
|
|
| Outer Conductor Integrity Temperature,
Celsius |
175 |
| Maximum Operating Temperature, Celsius |
125 |
|
|
| Outer Conductor |
1100 Aluminum |
| Dielectric |
PTFE |
| Center Conductor |
SPCW |
|
|
|